Hydrotech DLR-AP Ultraviolet Water Disinfection Unit User Manual

Browse online or download User Manual for Water purifiers Hydrotech DLR-AP Ultraviolet Water Disinfection Unit. Hydrotech DLR-AP Ultraviolet Water Disinfection Unit User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 23
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
INSTALLATION
OPERATION
AND
MAINTENANCE
MANUAL
MODELS
DLR-AP
SERIES NO'S
1
2
4
7
CAUTION
IT IS VERY IMPORTANT THAT THOSE RESPONSIBLE FOR
THE INSTALLATION OF THIS EQUIPMENT, AS WELL AS THE
OWNER/OPERATOR, READ THIS MANUAL AND CAREFULLY
FOLLOW THE INSTRUCTIONS AND GUIDELINES.
Sold by:
Manufactured by:
WEDECO Ideal Horizons, Inc.
3520 Westinghouse Blvd.
Charlotte, NC 28273
TEL: (704) 716-7600
FAX: (704) 716-7601
www.wedecouv.com
W
EDECO
DLR SERIES
ULTRAVIOLET
WATER
DISINFECTION UNIT
Page view 0
1 2 3 4 5 6 ... 22 23

Summary of Contents

Page 1 - DISINFECTION UNIT

INSTALLATION OPERATION AND MAINTENANCE MANUAL MODELS DLR-AP SERIES NO'S 1 2 4 7 CAUTION IT IS VERY IMPORTANT THAT THOS

Page 2 - Table of Contents

Installing the UV Lamp CAUTION UV lamp is very fragile. Do not handle it with bare hands. Use clean cotton gloves or cloth when handling lamp to k

Page 3 - THESE INSTRUCTIONS

Installing the UV Lamp, Continued Position Glo-Cap The Glo-Cap must be properly placed on the headpiece for the UV disinfection unit to work. Follow

Page 4

Pre-Start Up Sequence Before using the unit… Follow these steps before operating your WEDECO disinfection unit. Step Action 1 Check your plumbing:

Page 5

Start-Up Sequence Before using the unit… Follow the start-up procedures below. If your unit has… Then… No solenoid valve installed • Slowly fill

Page 6 - DIRECTION

Maintenance Required maintenance Periodically, you will need to perform routine maintenance procedures on your WEDECO UV disinfection unit. This sect

Page 7 - Requirements

Maintenance, Continued Cleaning the quartz sleeve, headpiece, & O-Ring The quartz sleeve must be kept clean to kill bacteria effectively. Your w

Page 8

Maintenance, Continued Replacing the O-Ring General maintenance for the O-Ring requires that you replace it every 365 days. If, however, during rout

Page 9 - Keyhole Slots

Maintenance Log Note You must perform routine maintenance in order to achieve optimum performance levels from your WEDECO UV disinfection unit. As yo

Page 10 - HORIZONTAL TAB

Parts List 87654313121111092111313128 AQ36799 19 AQ702576 110 AQ36942 210A AQ36992 211 * 212 * 213 * 414** * 115** * 116** AQ36944 1KEY # PART # QTY

Page 11 - Position Glo

Alarms Displays The front panel of the electrical control box has the following LED displays: LED Displays Diagram • LAMP ON: green • REPLACE

Page 12 - Step Action

Table of Contents Important Safety Instructions...

Page 13 - Start-Up Sequence

Troubleshooting Determining problem The troubleshooting guide gives you suggestions for resolving problems. If… Then… The unit is leaking water • E

Page 14 - Maintenance

Technical Specifications: DLR Series All prices and specifications are subject to change without notice. Technical Description Description The DLR Se

Page 15 - Maintenance, Continued

Technical Specifications: DLR Series, Continued Control Box DLR type 1 2 4 7 Width (inches) approx. 6.61 6.61 6.61 6.61 Height (inches) appro

Page 16

Warranty Note Save sales slip or cancelled check for proof of original purchase date to establish warranty period. FULL ONE-YEAR WARRANTY ON UV DISI

Page 17 - Maintenance Log

Important Safety Instructions WARNING! To guard against injury, basic safety precautions must be observed. READ AND FOLLOW ALL SAFETY INSTRUCTIONS

Page 18

Pre-Installation Instructions IMPORTANT Please read before installing your Ultraviolet System When this unit is wired in conjunction with another el

Page 19 - REPLACE LAMP

5 Select a location that meets the following guidelines. • The unit must be installed between the cold water source and the water heater as inlet t

Page 20 - Troubleshooting

Pre-Installation Instructions, Continued Figure 1: Installation Sequence Figure 1 shows a typical installation sequence. Note that all items may not

Page 21 - 2.76 2.76 4.02 4.02

Pre-Installation Instructions, Continued Figure 3: Unit Positioning Figure 3 shows proper water flow for horizontal or vertical installation. Make c

Page 22 - Model Characteristics

Installing the Disinfection Unit Attaching unit to wall Follow these steps to attach WEDECO UV disinfection chamber to the wall. Step Action Diag

Page 23 - Warranty

Mounting Electrical Control Box The electrical control box can be mounted on the wall (Option A) or on the disinfection chamber (Option B), accordi