Hydrotech LCP38 Leak Controller User Manual

Browse online or download User Manual for Water purifiers Hydrotech LCP38 Leak Controller. Hydrotech LCP38 Leak Controller User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0

Thank you for purchasing your Leak Controller™, a Water Controller Products device. Your Leak
Controller™ has been designed so it can be easily installed, operated, and maintained. Please read the
following instructions carefully, as we want you to enjoy all of the benefits of your product.
Installation and Operation Guide
For Models LCS25, LCS38, LCP25, LCP38

Features Benefits
USA manufactured NSF™ approved ball valve with
patent pending one-way spring release
Proven quality and reliability
Audio alarm and LED indicator See and hear the controller functioning
LeakLogic™ RISC based software Low battery power management, controller
monitoring, water leak detection sensitivity
Quick-Connect plumbing connections Fast installation without the need for a plumber for
tubing connections
Sensor with in-series connection capability Ability to connect as many sensors as needed to a
single controller
Complete testing capability One button test/silence/reset and direct sensor testing
Multiple uses Connect to many types of appliances and fixtures
Detachable Battery Holder Ease in changing batteries in difficult to access
locations
Separate 2 screw mounting plate Mounts in difficult places in seconds without a
template
Absorbent Sensor Mat Increased moisture sensitivity

Water Controller Products Inc. (WCP) has carefully tested and inspected the Leak
Controller™ before shipment, and hereby warrants our products to be free of defects in
material and workmanship for a period of 1 year from the date of the original purchase. You
should replace your controller every 5 years since it is in constant contact with your water
supply.
During the warranty period WCP shall, at its sole and absolute discretion, either repair or
replace free of charge any of our products that prove to be defective on inspection by WCP or
its authorized service representative. This warranty does not cover claims for damage due to
abuse, neglect, alteration, or attempted repair by unauthorized personnel, and is limited to
failures arising during normal use that are due to defects in material or workmanship in the
product.
ANY IMPLIED WARRANTIES, INCLUDING IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR USE AS SETFORTH IN
THESE INSTRUCTIONS, ARE LIMITED IN DURATION TO THE LENGTH OF THIS
LIMITED WARRANTY. USE OF THIS PRODUCT IS NOT A REPLACEMENT FOR
YOUR INSURANCE POLICY. IN NO EVENT WILL WCP BE LIABLE FOR
INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES RESULTING FROM THE
BREACH OF ANY EXPRESS OR IMPLIED WARRANTY, INCLUDING, AMONG
OTHER THINGS, DAMAGE TO PROPERTY, DAMAGE BASED ON INCONVENIENCE
OR ON LOSS OF THE USE OF THE PRODUCT, AND, TO THE EXTENT PERMITTED
BY LAW, DAMAGES FOR PERSONAL INJURY. THE LIABILITY OF WCP SHALL BE
LIMITED TO REPLACEMENT OF THE DEFECTIVE PRODUCT.
This warranty only applies to products sold and used in North America. For warranty
information in all other countries, please refer to your local distributor.

Use of the Leak Controller™ is restricted to water supply lines in a home, office or
recreational vehicle.
Do not allow small children to play with the controller, their fingers could get stuck or
injured inside of the controller valve. Only insert a pipe, tube or a fitting of the proper
size into the controller valve.
Operate the unit only with “AA” size alkaline type batteries.
Never open the cover to the controller, this will void the warranty and damage the
product.
The sensors can not having anything placed on top of them.
Do not connect the controller to a hot water line; connect only to the cold water supply.
Open the battery door and remove the battery holder. Take this moment to record the
installation date on the inside of the battery door, and on the
space below:
Original Battery Installation Date:
Additional Battery Change Dates:
Gently disconnect the battery holder from the snap connector.
Insert the 4 batteries into the battery holder slots, matching the
positive (+) and negative (-) terminals. Gently reconnect the
snap connector to the battery holder and insert the battery
holder into the battery compartment and close the battery door.
* You should see the blue LED light flash twice, hear the
speaker chirp twice, and then see the LED light flash once
every 5 seconds.
____________
____________
Turn the source water you will be connecting to off. Preferably, the controller will be installed
as far upstream (closest to where the water is access from the main plumbing) as possible from
the device you will be protecting, such as under the kitchen sink or behind an appliance. If you
are going to cut an existing plumbing line, allow for an extra ¾” of tubing on each side of the
controller valve as the valve requires ¾” of pipe or tubing to properly seal.
There are 2 ways to connect the controller to the water line that you want to protect depending
on the type and material of the tubing:
a) Plastic Tubing. Measure the length of tubing needed, and then add
at least one extra foot of tubing for both the incoming and outgoing
lines; this allows you to easily reach the controller. Cut the tubing
with a tube cutter, or very sharp razorblade. It is very important that
the cut is clean and straight through to ensure a good connection into
the quick-connect fittings.
b) Copper Tubing. Measure the length of tubing needed to easily reach the controller, you
may want to use some extra tubing in the event that you have to service the appliance or
controller, if this is the case, loop the extra tubing taking
care that the tubing enters the valve correctly. Use a
simple circular tube cutter (can be purchased from
hardware store) to cut through the tubing in a straight cut.
It is important that the cut is clean and straight through to
ensure a good connection into the quick-connect fittings.
c) Braided tubing. Visit www.leakcontroller.com
Avoid sharp changes in direction when routing the tubing. It is very important to have the
tubing inserted parallel to the valve, do not allow the tubing to exert any upward or downward
force on the valve connection.

Open the valve by turning the front Knob (with the finger-fitting wave grips) ¼ turn clockwise
to the green mark on the cover. Now the controller is open and
loaded. Press the front button and the alarm will sound to activate
the controllers’ test feature. The controller will beep and flash
four times and close the knob back to the red closed position.
Next, the alarm will sound, the LED light will flash twice, and the
controller circuitry will automatically reset itself. Again, open the
valve by turning the front knob ¼ turn clockwise to the green
mark on the cover.
Now the controller is ready to be connected to your water supply
and the controller is in the ready and armed state. The LED light
should be flashing once every 5 seconds, the speaker is off, and
the knob is in the green-armed position.
Package contents:
Main Leak Controller™ controller module with attached 4 1/2-foot sensor cable
4 “AA” size alkaline batteries
Metal Wall Mount Plate with 2 #8 mounting screws
1 sensor mat (paper towels OK for replacement)
* Additional sensors and cable lengths can be ordered


!
"#$
%
&
"
"
'
"!

____________
____________
____________
()&&(*)+("
,
-
Quick Reference
The Leak Controller is beeping, how do I shut it off?
The Leak Controller has activated due to one of the following:
1. water touching the sensor (leak or spill)
2. low battery
3. no testing for 2 years and is in maintenance mode
Check for leaks and fix if necessary. Dry sensor(s). Change the
batteries if in doubt. Hold the front button down until the blue
LED light goes solid (stops blinking) and release. Turn the knob
clockwise until locked in position.
Page view 0
1 2

Summary of Contents

Page 1

Thank you for purchasing your Leak Controller™, a Water Controller Products device. Your Leak Controller™ has been designed so it can be easi

Page 2 - ALWAYS CHECK THE SENSOR(S)

We have the following matrix to help you quickly identify the most common conditions that exist with your Leak Controller™. In the event

Comments to this Manuals

No comments