Installation of 1240 Reverse Osmosis Unit in the PURA Max
and Max Plus Point-of-Use Cooler
Please verify that all the required items have been received.
The 1240, 3 vessel reverse osmosis installation kit includes the following items.
1. 1240 three vessel reverse osmosis manifold (1) Part # 124010X0
2. Reverse osmosis membrane (1) Part # 33001033 (50 gallon per day)
3. Sediment/Carbon Cartridge (1) Part # 41400076
4. Carbon Cartridge (1) Part # 41400009
5. RO install kit (safety clips, drain and inlet tapping saddle valve, miscellaneous tubing) Part # 42903004
6. ¼”, Tubing, Red (6 FT) Part # 115206
7. ¼”, Tubing, White (10 FT) Part # 115200
8. Adapter, 1/4” x 3/8” (1) Part # PI201208S
9. Adapter, 1/4”X ¼” (1) Part # PI0408S
10. Flow control Red Tubing (1) Part #40600041
11. AirGap™ (1) Part # 44403001
Sanitizing Procedures
Please refer to 1240 RO manual and PURA POU Cooler manual for sanitizing instructions.
Intercomponent Quick Connect Connection
Please refer to page 2 of 1240 RO manual on how to use quick connect fittings.
1240 RO Installation Instructions
1. Install the membrane and filter cartridges in their respective vessels of the 1240
RO. Please refer to the 1240 Installation manual for details.
2. Open the lower door of the cooler as shown on the right.
3. Insert the ¼” white inlet water and ¼” drain flow control tubing inside the cooler
through the grommets. The inlet water tubing can be attached to the water source
feed line with the help of saddle-tapping valve. Please refer 1240 RO manual for
saddle-tapping valve installation. The installation of saddle-tapping connections
may be prohibited in certain local plumbing codes.
#54753 Rev. 10/09
Figure 1
Labeled
“From
Filtration”
¼” Feed
Line Empty
(right port)
Leak
Detector
Labeled “To
Filters”
¼” New
Feed Line
Page view 0
1 2 3 4

Summary of Contents

Page 1

1Installation of 1240 Reverse Osmosis Unit in the PURA Maxand Max Plus Point-of-Use CoolerPlease verify that all the required items have been received

Page 2

24. Attach the end of the ¼” feed line that was inserted in step 2 into the open fitting on the bottom right sideof the leak detector.5. Attach the ¼”

Page 3

3Installation of Quick Connect Pentek Cartridges in the PURAMax and Max Plus Point-of-Use CoolerPlease verify that all the required items have been re

Page 4 - ¼” Tubing

4Quick Connect Pentek Cartridge Installation Instructions Cont’d3. Attach the end of the ¼” feed line that was installed in step 2 into the open fitti