Fleck SXT Timer
Service Manual
42713 Rev F JL10
TABLE OF CONTENTS
JOB SPECIFICATION SHEET ...............................................1
INSTALLATION ......................................................................2
START-UP INSTRUCTIONS ..................................................2
TIMER FEATURES ................................................................3
TIMER OPERATION ..............................................................4
MASTER PROGRAMMING MODE CHART ..........................5
MASTER PROGRAMMING MODE ........................................6
USER PROGRAMMING MODE .............................................9
DIAGNOSTIC PROGRAMMING MODE ................................10
CONTROL VALVE ASSEMBLY ..............................................11
VALVE POWERHEAD ASSEMBLY ........................................12
3/4" TURBINE METER ASSEMBLY .......................................13
BYPASS VALVE ASSEMBLY (PLASTIC) ...............................14
BYPASS VALVE ASSEMBLY (METAL) ..................................15
2300 SAFETY BRINE VALVE.................................................16
2310 SAFETY BRINE VALVE.................................................17
TROUBLESHOOTING ...........................................................18
WATER CONDITIONER FLOW DIAGRAMS .........................20
WIRING DIAGRAM ................................................................21
SERVICE INSTRUCTIONS ....................................................22
SERVICE ASSEMBLIES ........................................................24
JOB SPECIFICATION SHEET
Job Number: ___________________________________________________
Model Number: _________________________________________________
Water Hardness: _______________________________________ ppm or gpg
Capacity Per Unit: _______________________________________________
Mineral Tank Size: ______________ Diameter: ________ Height: _________
Salt Setting per Regeneration: _____________________________________
1. Type of Timer:
A. 7 Day or 12 Day
B. Meter Initiated
2. Downow: Upow UpowVariable
3. Meter Size:
A. 3/4" Std Range (125 - 2,100 gallon setting)
B. 3/4" Ext Range (625 - 10,625 gallon setting)
C. 1" Std Range (310 - 5,270 gallon setting)
D. 1" Ext Range (1,150 - 26,350 gallon setting)
E. 1-1/2" Std Range (625 - 10,625 gallon setting)
F. 1-1/2" Ext Range (3,125 - 53,125 gallon setting)
G. 2" Std Range (1,250 - 21,250 gallon setting)
H. 2" Ext Range (6,250 - 106,250 gallon setting)
I. 3" Std Range (3,750 - 63,750 gallon setting)
J. 3" Ext Range (18,750 - 318,750 gallon setting)
K. Electronic _________ Pulse Count ________ Meter Size _______
4. System Type:
A. System #4: 1 Tank, 1 Meter, Immediate, or Delayed Regeneration
B. System #4: Time Clock
C. System #4: Twin Tank
D. System #5: 2-5 Tanks, Interlock Mechanical
2-4 Tanks, Interlock Electronic
Meter per unit for Mechanical and Electronic
E. System #6: 2-5 Tanks, 1 Meter, Series Regeneration, Mechanical
2-4 Tanks, 1 Meter, Series Regeneration, Electronic
F. System #7: 2-5 Tanks, 1 Meter, Alternating Regeneration,
Mechanical
2 Tanks only, 1 Meter, Alternating Regeneration,
Electronic
G. System #9: Electronic Only, 2-4 Tanks, Meter per Valve, Alternating
H. System #14: Electronic Only, 2-4 Tanks, Meter per Valve. Brings
units on and ofine based on ow.
5. TimerProgramSettings:
A. Backwash: ___________________________________ Minutes
B. Brine and Slow Rinse: __________________________ Minutes
C. Rapid Rinse: _________________________________ Minutes
D. Brine Tank Rell: ______________________________ Minutes
E. Pause Time: __________________________________ Minutes
F. Second Backwash: ____________________________ Minutes
6. DrainLineFlowControl: ______________________________gpm
7. Brine Line Flow Controller: ____________________________gpm
8. Injector Size#: ____________________________________________
9. Piston Type:
A. Hard Water Bypass
B. No Hard Water Bypass
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - Fleck SXT Timer

Fleck SXT TimerService Manual 42713 Rev F JL10TABLE OF CONTENTSJOB SPECIFICATION SHEET ...1INSTALLATI

Page 2 - TIMERFEATURES

ItemNo. QTY PartNo. Description 1 ...1 ... 13881 ...Bracket, Hinge Timer 3 ...1 ... 14265 ...

Page 3 - TIMER OPERATION

9000/9100/9500TWINTANKTIMERASSEMBLYItemNo. QTY PartNo. Description 1 ...1 ... 13881 ...Bracket, Hinge Timer 2

Page 4 - MASTER PROGRAMMING MODE

3/4"PLASTICTURBINEMETERASSEMBLY19797 Rev AItemNo. QTY PartNo. Description 1 ...1 ... 19791-01 ...Meter Cable A

Page 5

METER ASSEMBLYItemNo. QTY PartNo. Description 1 ...1 ... 13874 ...Body, Meter, 5600 2 ...1 ... 1

Page 6

3/4" BRASS PADDLE METER ASSEMBLYItemNo. QTY PartNo. Description 1 ...1 ... 11206 ...Gasket, Fitting 2 ...

Page 7

1" BRASS PADDLE METER ASSEMBLYItemNo. QTY PartNo. Description 1 ...1 ... 14959 ...Body, Meter, 2750 2 ...

Page 8 - USERPROGRAMMINGMODE

INLINEPLASTICTURBINEMETERASSEMBLYItemNo. QTY PartNo. Description 1 ...1 ... 17542 ...Flow Straightener 2 ...

Page 9 - DIAGNOSTIC PROGRAMMING MODE

1-1/2" BRASS PADDLE METER ASSEMBLYItemNo. QTY PartNo. Description 1 ...1 ... 17569 ...Body, Meter, 2850/9500

Page 10 - 10 • JL10 Fleck SXT Timer

3/4",1"or1-1/2"PADDLEWHEELMETER CAP ASSEMBLYItemNo. QTY PartNo. Description 1 ...1 ... 14716 ...

Page 11 - ASSEMBLY

TROUBLESHOOTINGErrorCodesNOTE:ErrorcodesappearontheInServicedisplay.ErrorCode Error Type Cause ResetandRecovery0 Cam Sense ErrorThe valve

Page 12

TIMERFEATURESParameterDisplayDataDisplayPMIndicatorFlow Indicatorx1000 IndicatorServiceIconProgrammingIconExtra CycleButtonUpButtonDownButtonError/In

Page 13 - METER ASSEMBLY

2510SXTWIRINGDIAGRAMSCAMHC AMCN.O.N.C.SW2CN.O.N.C.SW1VDMT1H --SWHITEN NGREENTMPURPLEORANGEWHITEYELSPWR VDOMETER+BLUEWT/BLKBLUEBLACKH N.O .P2REDBLACK

Page 14 - 3/4" BRASS PADDLE METER

2750SXT/2850SXTWIRINGDIAGRAMSCAMHC AMCN.O.N.C.SW2CN.O.N.C.SW1VDMPWM1.0"T1H --SWHITEN NGREENPURPLEORANGEWHITEYELSPWR VDOMETER+BLUEWT/BLKBLUEBLAC

Page 15 - Fleck SXT Timer JL10 • 15

9000SXT/9100SXT/9500SXTWIRINGDIAGRAM42743 Rev A22 • JL10 Fleck SXT Timer

Page 16 - INLINEPLASTICTURBINEMETER

SERVICEASSEMBLIESMeter60086-50 ...Meter Assy, 3/4", Electronic 2510/6600/670060613...Meter Assy, 2750 El

Page 17

© 2010 Pentair Residential Filtration, LLC 42713 Rev F JL10

Page 18 - METER CAP ASSEMBLY

TIMER OPERATIONMeterImmediateControlA meter immediate control measures water usage and regenerates the system as soon as the calculated system capac

Page 19 - TROUBLESHOOTING

MASTER PROGRAMMING MODE CHARTCaution:BeforeenteringMasterProgramming,pleasecontactyourlocalprofessionalwaterdealer.MasterProgrammingOpti

Page 20 - 2510SXTWIRINGDIAGRAM

MASTER PROGRAMMING MODEWhen the Master Programming Mode is entered, all available option setting displays may be viewed and set as needed. Depending o

Page 21 - Fleck SXT Timer JL10 • 21

5.TankinService(DisplayCodeTS)Press the Extra Cycle button. Use this display to set whether tank one or tank two is in service. This option sett

Page 22 - 22 • JL10 Fleck SXT Timer

12.RegenerationTimePress the Extra Cycle button. Use this display to set the Regeneration Time. This setting species the time of day the control wi

Page 23 - SERVICEASSEMBLIES

USERPROGRAMMINGMODEUserProgrammingModeOptionsAbbreviation Parameter DescriptionDO Day Override The timer’s day override settingRT Regeneration Ti

Page 24

DIAGNOSTIC PROGRAMMING MODEDiagnosticProgrammingModeOptionsAbbreviation Parameter DescriptionFR Flow Rate Displays the current outlet ow ratePF Pe